Included with MRCOOL Smart Thermostat Purchase:
Tools Needed:
Drill with 3/16" Drill Bit (for mounting anchors)
Phillips Screwdriver
Wire Stripper (optional)
Hammer (optional)
Pencil (optional)
Preparations:
Power off your system: Turn off the power at the breaker or disconnect. Allow 15-20 minutes for it to de-energize before starting the installation.
Verify no air is coming from the system: If you're working with a boiler, ensure the main flame is out.
Check the thermostats backplate for any of these indicators and contact support for assistance.
Installing Your MRCOOL Smart Thermostat
-
Power Source
Ensure the MRCOOL Smart Thermostat is connected to a 24V hardwire power source. -
Placement
Install the thermostat within line of sight of your mini split system in the same room for optimal communication and performance. -
Prepare the Backplate
-
Pull the labeled wires through the center hole of the MRCOOL backplate.
-
Use the provided drywall anchors and screws to securely mount the backplate to the wall.
-
-
Wiring
Follow the wiring diagram below to connect the wires properly. -
Mount the Thermostat
Align the MRCOOL Smart Thermostat with the backplate and press gently until it clicks into place.
Wiring the Thermostat:
- Do you have multiple R-wires? (This includes R, RC, and RH).
- If yes, connect RH → RH and R or RC → RC.
- If you only have one R, RC, or RH wire, insert it into the RC terminal.
- Insert the remaining wires into their corresponding terminals. Press the terminal block buttons for easier insertion.
- Gently push any excess wires back into the wall to prevent drafts.