An error code is a way for an HVAC system (like a mini-split or central unit) to communicate that something isn’t working properly.
Instead of just shutting down with no explanation, the system will flash a specific code — usually letters and numbers — on a display or indicator light.
Each error code points to a specific issue, like:
-
Electrical problems
-
Sensor malfunctions
-
Communication failures between components
-
Refrigerant pressure issues
-
Motor faults
-
Temperature problems
Central Ducted Condenser:
| Model |
|
CENTRAL-18-HP-C-230-25 |
|
CENTRAL-24-HP-C-230-25 |
|
CENTRAL-30-HP-C-230-25 |
|
CENTRAL-36-HP-C-230-00 |
|
CENTRAL-48-HP-C-230-00 |
|
CENTRAL-60-HP-C-230-00 |
Diagnostic Codes:
| Error Code: | Error: |
| EH 00 | Indoor PCB |
| EL 01 | Indoor PCB, Outdoor PCB, or Reactor |
| EH 03 | Indoor PCB, Indoor fan motor |
| EH 60 | Indoor PCB, T1 sensor |
| EH 61 | Indoor PCB, T2 Sensor |
| EH 62 | Indoor PCB, T2B Sensor |
| EH 65 | Indoor PCB, T2A Sensor |
| EL 0C | Indoor PCB, Additional refrigerant |
| EH 0E | Indoor PCB, Water-level switch, or Water pump |
| EC 53 | Outdoor PCB, T4 Sensor |
| EC 54 | Outdoor PCB, TP Sensor |
| EC 51 | Outdoor PCB |
| EC 5C | Outdoor PCB, Pressure sensor |
| EC 52 | Outdoor PCB, T3 Sensor |
| EC 07/71/72/73 | Outdoor PCB, Outdoor fan motor |
| PC 00 | Outdoor PCB, Outdoor fan motor, Compressor, IPM module board |
| PC 01 | Outdoor PCB, Reactor, IPM module board |
| PC 02 | Outdoor PCB, Outdoor fan motor, IPM module board |
| PC 04 | Outdoor PCB, Outdoor fan motor, Compressor, IPM module board |
| PC 03 | Outdoor PCB, Low pressure protector, Additional refrigerant |
| EL 16 | Outdoor PCB, Data adapter board |
| EH 0b | Indoor PCB, Data adapter board |
| PC 06 | Outdoor PCB, TP Sensor, High pressure valve, Additional refrigerant |
| PC 08/44/49 | Outdoor PCB, Outdoor fan motor, Reactor, IPM module board |
| PC 0A | Outdoor PCB, Outdoor fan motor, T3 Sensor, Additional refrigerant |
| PC 0F | Outdoor PCB, Reactor, |
| PC 41 | Outdoor PCB |
| PC 43 | Outdoor PCB, Compressor |
| PC 10/11/12 | Outdoor PCB, Reactor, IPM module board |
| PC 30 | Outdoor PCB, Outdoor fan motor, High pressure protector |
| PC 31 | Outdoor PCB, Low pressure protector, Additional refrigerant |
| PC 40 | Outdoor PCB, IPM module board, Electric control box |
・・・──────────────────────────────・・・
Central Ducted Air Handler:
| Model |
|
CENTRAL-18-HP-MUAH-230-25 |
|
CENTRAL-24-HP-MUAH-230-25 |
|
CENTRAL-30-HP-MUAH-230-25 |
|
CENTRAL-36-HP-MUAH-230-00 |
|
CENTRAL-48-HP-MUAH-230-00 |
|
CENTRAL-60-HP-MUAH-230-00 |
Diagnostic Codes:
| Error Code: | Error: |
| EH 00 | Indoor unit EEPROM parameter error |
| EL 01 | Indoor / outdoor unit communication error |
| EL 16 | Communication malfunction between adapter board and outdoor main board |
| EH 03 | The indoor fan speed is operating outside of the normal range(for some models) |
| EH 60 | Indoor room temperature sensor T1 is in open circuit or has short circuited |
| EH 61 | Evaporator coil temperature sensor T2 is in open circuit or has short circuited |
| EH 62 | Evaporator coil temperature sensor T2B is in open circuit or has short circuited |
| Eh 65 | Evaporator coil temperature sensor T2A is in open circuit or has short circuited |
| EL 0C | Refrigerant Leakage Detection(for some models |
| EH 0b | Communication error between indoor two chips |
| EH 0E | Water-level alarm malfunction |
| EC 53 | Outdoor room temperature sensor T4 is in open circuit or has short circuited |
| EC 52 | Condenser coil temperature sensor T3 is in open circuit or has short circuited |
| EC 54 | Compressor discharge temperature sensor TP is in open circuit or has short circuited |
| EC 56 | Evaporator coil outlet temperature sensor T2B is in open circuit or has short circuited(for freematch indoor units) |
| EC 51 | Outdoor unit EEPROM parameter error |
| EC 07 | The outdoor fan speed is operating outside of the normal range(for some models) |
| PC 00 | IPM malfunction or IGBT over-strong current protection |
| PC 01 | Over voltage or over low voltage protection |
| PC 02 | Top temperature protection of compressor or High temperature protection of IPM module |
| PC 04 | Inverter compressor drive error |
| PC 03 | Low pressure protection (for some models) |
| EC 0d | Outdoor unit malfunction |
| PC 0L | Low ambient temperature protection |
| FL 09 | Mismatch between the new and old platforms |
・・・──────────────────────────────・・・
Hyper Heat Condenser:
| Model |
|
CENTRAL-24-HP-C-230A00 |
|
CENTRAL-36-HP-C-230A00 |
|
CENTRAL-48-HP-C-230A00 |
|
CENTRAL-60-HP-C-230A00 |
Diagnostic Codes:
| Error Code: | Error: |
| EH 00 | Indoor PCB |
| EL 01 | Indoor PCB, Outdoor PCB, or Reactor |
| EH 03 | Indoor PCB, Indoor fan motor |
| EH 60 | Indoor PCB, T1 sensor |
| EH 61 | Indoor PCB, T2 Sensor |
| EH 62 | Indoor PCB, T2B Sensor |
| EH 65 | Indoor PCB, T2A Sensor |
| EL 0C | Indoor PCB, Additional refrigerant |
| EH 0E | Indoor PCB, Water-level switch, or Water pump |
| EC 53 | Outdoor PCB, T4 Sensor |
| EC 54 | Outdoor PCB, TP Sensor |
| EC 51 | Outdoor PCB |
| EC 5C | Outdoor PCB, Pressure sensor |
| EC 52 | Outdoor PCB, T3 Sensor |
| EC 07/71/72/73 | Outdoor PCB, Outdoor fan motor |
| PC 00 | Outdoor PCB, Outdoor fan motor, Compressor, IPM module board |
| PC 01 | Outdoor PCB, Reactor, IPM module board |
| PC 02 | Outdoor PCB, Outdoor fan motor, IPM module board |
| PC 04 | Outdoor PCB, Outdoor fan motor, Compressor, IPM module board |
| PC 03 | Outdoor PCB, Low pressure protector, Additional refrigerant |
| EL 16 | Outdoor PCB, Data adapter board |
| EH 0b | Indoor PCB, Data adapter board |
| PC 06 | Outdoor PCB, TP Sensor, High pressure valve, Additional refrigerant |
| PC 08/44/49 | Outdoor PCB, Outdoor fan motor, Reactor, IPM module board |
| PC 0A | Outdoor PCB, Outdoor fan motor, T3 Sensor, Additional refrigerant |
| PC 0F | Outdoor PCB, Reactor, |
| PC 41 | Outdoor PCB |
| PC 43 | Outdoor PCB, Compressor |
| PC 10/11/12 | Outdoor PCB, Reactor, IPM module board |
| PC 30 | Outdoor PCB, Outdoor fan motor, High pressure protector |
| PC 31 | Outdoor PCB, Low pressure protector, Additional refrigerant |
| PC 40 | Outdoor PCB, IPM module board, Electric control box |
・・・──────────────────────────────・・・
Hyper Heat Air Handler:
| Model |
|
CENTRAL-24-HP-MUAH230A00 |
|
CENTRAL-36-HP-MUAH230A00 |
|
CENTRAL-48-HP-MUAH230A00 |
|
CENTRAL-60-HP-MUAH230A00 |
Diagnostic Codes:
| Error Code: | Error: |
| EH 00 | Indoor unit EEPROM parameter error |
| EL 01 | Indoor / outdoor unit communication error |
| EL 16 | Communication malfunction between adapter board and outdoor main board |
| EH 03 | The indoor fan speed is operating outside of the normal range(for some models) |
| EH 60 | Indoor room temperature sensor T1 is in open circuit or has short circuited |
| EH 61 | Evaporator coil temperature sensor T2 is in open circuit or has short circuited |
| EH 62 | Evaporator coil temperature sensor T2B is in open circuit or has short circuited |
| Eh 65 | Evaporator coil temperature sensor T2A is in open circuit or has short circuited |
| EL 0C | Refrigerant Leakage Detection(for some models |
| EH 0b | Communication error between indoor two chips |
| EH 0E | Water-level alarm malfunction |
| EC 53 | Outdoor room temperature sensor T4 is in open circuit or has short circuited |
| EC 52 | Condenser coil temperature sensor T3 is in open circuit or has short circuited |
| EC 54 | Compressor discharge temperature sensor TP is in open circuit or has short circuited |
| EC 56 | Evaporator coil outlet temperature sensor T2B is in open circuit or has short circuited(for freematch indoor units) |
| EC 51 | Outdoor unit EEPROM parameter error |
| EC 07 | The outdoor fan speed is operating outside of the normal range(for some models) |
| PC 00 | IPM malfunction or IGBT over-strong current protection |
| PC 01 | Over voltage or over low voltage protection |
| PC 02 | Top temperature protection of compressor or High temperature protection of IPM module |
| PC 04 | Inverter compressor drive error |
| PC 03 | Low pressure protection (for some models) |
| EC 0d | Outdoor unit malfunction |
| PC 0L | Low ambient temperature protection |
| FL 09 | Mismatch between the new and old platforms |
・・・──────────────────────────────・・・
2nd Gen Hyper Heat:
| Model |
|
CENTRAL-24-HP-C-230B00-O |
|
CENTRAL-30-HP-C-230B00-O |
|
CENTRAL-36-HP-C-230B00-O |
|
CENTRAL-48-HP-C-230B00-O |
|
CENTRAL-60-HP-C-230B00-O |
Diagnostic Codes:
| Error Code: | Error: |
| EC 07 | ODU fan speed out of control |
| EC 51 | ODU EEPROM parameter error |
| EC 52 | ODU coil temperature sensor (T3) error |
| EC 53 | ODU ambient temperature sensor (T4) error |
| EC 54 | Compressor discharge temperature sensor (T4) error |
| EC 55 | ODU IPM module temperature sensor malfunction |
| EC 57 | Refrigerant pipe temperature sensor error |
| EC SC | Pressure sensor failure |
| EL 01 | IDU & ODU communication error |
| EL 16 | Communication malfunction between adapter board and ODU main board |
| PC 00 | IPM Module Protection |
| PC 02 | Compressor top (or IPM) temperature protection / Refrigerant sensor error |
| PC 06 | Discharge temperature protection of compressor |
| PC 08 | Outdoor overcurrent protection |
| PC 0A | High temperature protection of condenser |
| PC 0F | PFC Module Protection |
| PC 10 | ODU low AC voltage protection |
| PC 11 | ODU main control board DC bus high voltage protection |
| PC 12 | ODU main control board DC bus low voltage protection / 341 MCE error |
| PC 30 | System high pressure protection |
| PC 31 | System low pressure protection |
| PC 40 | Communication error between ODU main chip and compressor driven chip |
| PC 41 | Compressor current sampling failure |
| PC 42 | Compressor start failure of outdoor unit |
| PC 43 | ODU compressor lack phase protection |
| PC 44 | ODU zero speed protection |
| PC 45 | ODU IR chip drive failure |
| PC 46 | Compressor speed out of control |
| PC 49 | Compressor overcurrent failure |
| LC 06 | High temperature protection of Inverter Module (IPM) |
| PH 90 | High temperature protection of evaporator |
| PH 91 | Low temperature protection of evaporator |
✅ Why Error Codes Matter:
They help technicians, installers, and even homeowners quickly understand where to start troubleshooting without guessing.
✅ Important Tip:
While error codes point you in the right direction, they don’t always tell you the exact part that’s failed — just the general area or type of problem. Further testing is often needed!